Handling connectivity errors in alerts

Connectivity issues are one of the common causes of misleading alerts or unnoticed failures.

Maybe your target went offline, or Prometheus couldn’t scrape it. Or maybe your alert query failed because its target timed out or the network went down. These situations might look similar, but require different considerations in your alerting setup.

This guide walks through how to detect and handle these types of failures, whether you’re writing alert rules in Prometheus, using Grafana Alerting, or combining both. It covers both availability monitoring and alert query failures, and outlines strategies to improve the reliability of your alerts.

Understanding connectivity issues in alerts

Typically, connectivity issues fall into a few common scenarios:

  • Servers or containers crashed or were shut down.
  • Service overload or timeout.
  • Misconfigured authentication or incorrect permissions.
  • Network issues like DNS problems or ISP outages.

When we talk about connectivity errors in alerting, we’re usually referring to one of two use cases:

  1. Your target is down or unreachable.
    The service crashed, the host was down, or a firewall or DNS issue blocked the connection. These are availability problems.

  2. Your alert query failed.
    The alert couldn’t evaluate its query—maybe because the data source timed out or an invalid query. These are execution errors.

It helps to separate these cases early, because they behave differently and require different strategies.

Keep in mind that most alert rules don’t hit the target directly. They query metrics from a monitoring system like Prometheus, which scrapes data from your actual infrastructure or application. That gives us two typical alerting setups where connectivity issues can show up:

  1. Alert rule → Target
    For example, an alert rule querying an external data source like a database.

  2. Alert rule → Prometheus ← Target
    More common in observability stacks. For instance, Prometheus scrapes a node or container, and the alert rule queries the metrics later.

    In this second setup, you can run into connectivity issues on either side. If Prometheus fails to scrape the target, your alert rule might not fire, even though something is likely wrong.

Detecting target availability with the Prometheus up metric

Prometheus scrapes metrics from its targets regularly, following the scrape_interval period. The default scrape interval is 60 seconds, which is generally considered common practice.

Prometheus provides a built-in metric called up for every scrape target, a simple method to indicate whether scraping is successful:

  • up == 1: Your target is reachable; Prometheus collected the target metrics as expected.

  • up == 0: Prometheus couldn’t reach your target—indicating possible downtime or network errors.

A typical PromQL expression for an alert rule to detect when a target becomes unreachable is:

up == 0

But this alert rule might result in noisy alerts as one brief hiccup (a single scrape failure) will fire the alert. To reduce noise, you should add a delay:

up == 0 for: 5m

The for option in Prometheus (or pending period in Grafana) delays the alert until the condition has been true for the full duration.

In this example, waiting for 5 minutes helps skip temporary hiccups. Since Prometheus scrapes metrics every minute by default, the alert only fires after five consecutive failures.

However, this kind of up alert has a few gotchas:

  • Failures can slip between scrape intervals: An outage that starts and ends between two evaluations go undetected. You could shorten the for duration, but this might lead to temporary hiccups triggering false alarms.
  • Intermittent recoveries reset the for timer: A single successful scrape resets the alert timer, masking intermittent outages.

Brief connectivity drops are common in real-world environments, so expect some flakiness in up alerts. For example:

Scrape result (up)Alert rule evaluation
00:00 up == 0Timer starts
01:00 up == 0Timer continues
02:00 up == 0Timer continues
03:00 up == 1Successful scrape resets timer
04:00 up == 0Timer starts again
05:00 up == 0No alert yet—timer hasn’t reached the for duration

The longer the period, the more likely this is to happen.

A single recovery resets the alert, that’s why up == 0 for: 5m can sometimes be unreliable. Even if the target is down most of the time, the alert didn’t fire, leaving you unaware of a potential persistent issue.

Using avg_over_time

One way to work around these issues is to smooth the signal by averaging the up metric over a similar or longer period:

avg_over_time(up[10m]) < 0.8

This alert rule fires when the target is unreachable for more than 20% of the last 10 minutes, rather than looking for consecutive scrape failures. With a one-minute scrape interval, three or more failed scrapes within the last 10 minutes will now trigger the alert.

Since this query uses a threshold and time window to control accuracy, you can now lower the for duration (or pending period in Grafana) to something shorter—0m or 1m—so the alert fires faster.

This approach gives you more flexibility in detecting real crashes or network issues. As always, adjust the threshold and period based on your noise tolerance and how critical the target is.

Using synthetic checks for monitoring external availability

Prometheus often runs inside the same network as the target it monitors. That means Prometheus might be able to reach the target, but doesn’t ensure it’s reachable to users on the outside.

Firewalls, DNS misconfigurations, or other network issues might block public traffic while Prometheus scraping up successfully.

This is where synthetic monitoring helps. Tools like the Blackbox Exporter let you continuously verify whether a service is available and reachable from outside your network—not just internally.

The Blackbox Exporter exposes the results of these checks as metrics, which Prometheus can scrape like any other target. For example, the probe_success metric reports whether the probe was able to reach the service. The setup looks like this:

Alert rules → Prometheus ← Blackbox Exporter (external probe) → Target

To detect when a service isn’t reachable externally, you can define an alert using the probe_success metric:

probe_success == 0 for: 5m

This alert fires when the probe has failed continuously for 5 minutes—indicating that the service couldn’t be reached from the outside.

You can then combine internal and external checks to make the detection of connectivity errors more reliable. This alert catches when the internal scrape fails or the service is externally unreachable.

up == 0 or probe_success == 0

As with the up metric, you might want to smooth this out using avg_over_time() for more robust detection. The smooth version might look like:

avg_over_time(up[10m]) < 0.8 or avg_over_time(probe_success[10m]) < 0.8

This alert fires when Prometheus couldn’t scrape the target successfully for more than 20% of the past 10 minutes, or when the external probes have been failing more than 20% of the time. This smoothing technique can be applied to any binary availability signal.

When only some hosts stop reporting

In many setups, Prometheus scrapes multiple hosts under the same target — for example, a fleet of servers or containers behind a common job label. It’s common for one host to go offline while the others continue to report metrics normally.

If your alert only checks the general up metric without breaking it down by labels (like instance, host, or pod), you might miss when a host stops reporting. For example, an alert that looks only at the aggregated status of all instances will likely fail to catch when individual instances go missing.

This isn’t a connectivity error in this context — it’s not that the alert or Prometheus can’t reach anything, it’s that one or more specific targets have gone silent. These kinds of problems aren’t caught by up == 0 alerts.

For these cases, see the complementary guide on handling missing data — it covers common scenarios where the alert queries return no data at all, or where only some targets stop reporting. These aren’t full availability failures or execution errors, but they can still lead to blind spots in alert detection.

Handling query errors in Grafana Alerting

Not all connectivity issues come from targets going offline. Sometimes, the alert rule fails when querying its target. These aren’t availability problems—they’re query execution errors: maybe the data source timed out, the network dropped, or the query was invalid.

These errors lead to broken alerts. But they come from a different part of the stack: between the alert rule and the data source, not between the data source (e.g., Prometheus) and its target.

This difference matters. Availability issues are typically handled using metrics like up or probe_success but execution errors require a different setup.

Grafana Alerting has built-in handling for execution errors, regardless of the data source. That includes Prometheus, and others like Graphite, InfluxDB, PostgreSQL, etc. By default, Grafana Alerting automatically handles query errors so you don’t miss critical failures. When an alert rule fails to execute, Grafana fires a special DatasourceError alert.

You can configure this behavior depending on how critical the alert is—and whether you already have other alerts detecting the issue. In Configure no data and error handling, click Alert state if execution error or timeout, and choose the desired option for the alert:

  • Error (default): Triggers a separate DatasourceError alert. This default ensures alert rules always inform about query errors but can create noise.

  • Alerting: Treats the error as if the alert condition is firing. Grafana transitions all existing instances for that rule to the Alerting state.

  • Normal: Ignores the query error and transitions all alert instances to the Normal state. This is useful if the error isn’t critical or if you already have other alerts detecting connectivity issues.

  • Keep Last State: Keeps the previous state until the query succeeds again. Suitable for unstable environments to avoid flapping alerts.

    A screenshot of the `Configure error handling` option in Grafana Alerting.

This applies even when alert rules query Prometheus itself—not just external data sources.

Designing alerts for connectivity errors

In practice, start by deciding if you want to create explicit alert rules — for example, using up or probe_success — to detect when a target is down or having connectivity issues.

Then, for each alert rule, choose the error-handling behavior based on whether you already have dedicated connectivity alerts, the stability of the target, and how critical the alert is. Prioritize alerts based on symptom severity rather than just infrastructure signals that might not impact users.

Reducing redundant error notifications

A single data source error can lead to multiple alerts firing simultaneously, sometimes bombarding you with many alerts and generating too much noise.

As described previously, you can control the error-handling behavior for Grafana alerts. The Keep Last State or Normal option prevents alerts from firing and helps avoid redundant alerts, especially for services already covered by up or probe_success alerts.

When using the default behavior, a single connectivity error will likely trigger multiple DatasourceError alerts.

These alerts are separate from the original alerts—they’re not just a different state of the original alert. They fire immediately, ignore the pending period, and don’t inherit all the labels. This can catch you off guard if you expect them to behave like the original alerts.

Consider not treating these alerts in the same way as the original alerts, and implement dedicated strategies for their notifications:

  • Reduce duplicate notifications by grouping DatasourceError alerts. Use the datasource_uid label to group errors from the same data source.

  • Route DatasourceError alerts separately, sending them to different teams or channels depending on their impact and urgency.

For details on how to configure grouping and routing, refer to handling notifications and No Data and Error alerts documentation.

Wrapping up

Connectivity issues are one of the common causes of noisy or misleading alerts. This guide covered two distinct types:

  • Availability issues, where the target itself is down or unreachable (e.g., due to a crash or network failure).

  • Query execution errors, where the alert rule can’t reach its data source (e.g., due to timeouts, invalid queries, or data source outages).

These problems come from different parts of your stack, and require its own techniques. Prometheus and Grafana allow you to detect them, and combining distinct techniques can make your alerts more resilient.

With Prometheus, avoid relying solely on up == 0. Smooth queries to account for intermittent failures, and use synthetic monitoring to detect reachability issues from outside your network.